ISO/IEC 17025 Accredited Calibration Laboratory
Precision you can trust
Temprecord provides ISO/IEC 17025 accredited calibration services through our IANZ-accredited laboratory in New Zealand.
Our calibration services support accurate, reliable, and traceable temperature and humidity monitoring for regulated industries including pharmaceutical, food production, healthcare, research, logistics, storage, and warehousing.
Every calibration is performed to international standards, giving you confidence in your measurements and audit-ready documentation when compliance matters.
Why Choose Temprecord Calibration?
ISO/IEC 17025 Accredited
Temprecord’s calibration laboratory is accredited to ISO/IEC 17025 by International Accreditation New Zealand (IANZ), supporting traceable results and internationally recognised confidence.
Temperature & Humidity Calibration
We provide 3-point temperature calibrations and 2-point humidity calibrations across a wide range of monitoring applications, including ultra-low temperature environments.
Low Measurement Uncertainty
Temprecord achieves uncertainty as low as ±0.2°C over the range of -20°C to +50°C, helping ensure high-precision monitoring for critical applications.
Built-In Logger Corrections
Temprecord data loggers are adjusted with correction factors during manufacturing, helping improve data accuracy and reduce user error.
Audit-Ready Certificates
Each calibration includes a traceable certificate suitable for regulatory submissions, audits, validation, and internal quality assurance.
Calibration Accuracy
Temprecord’s standard 3-point temperature calibration achieves:
- ±0.2°C over -20°C to +50°C
- ±0.2°C over -40°C to +50°C for low-temperature loggers
- ±0.8°C across cryogenic points including -196°C, -90°C, and -38°C
Humidity loggers are calibrated with an expanded uncertainty of ±3% RH across the range of 12% to 85% RH.
All uncertainties are expressed at a 95% confidence level with a coverage factor of k = 2.
Designed for Regulated Industries
Temprecord calibration services are ideal for:
- Pharmaceutical and healthcare monitoring
- Food safety and HACCP programs
- Laboratory and research environments
- Cold chain transport and logistics
- Storage and warehousing
- Quality assurance and compliance programs
Trusted Accuracy, Traceable Results
With ISO/IEC 17025 accreditation and ISO 9001 certification, Temprecord provides reliable calibration services for businesses that require confidence, compliance, and traceability in their temperature and humidity monitoring systems.
Scope of Accreditation
Three Point Temperature Calibrations
| Calibration Temperature Range | Least Uncertainty of Calibrations (Best Measurement) |
For Data Loggers without probes fitted (Internal sensor)
| -15ºC to 40°C | ± 0.061°C (routinely ±0.2°C from -15 to 40°C) in the F3 machine. |
For Data Loggers with probes fitted (External sensor)
| -24°C to 130°C | ±0.056°C (routinely ±0.2°C from -20 to 50°C) in dry block calibrator. |
| ±0.036°C (routinely ±0.2°C from -20 to 50°C) in stirred liquid baths. |
Single Point Temperature Calibrations & Re-Calibration Data Loggers
| Calibration Temperature Range | Least Uncertainty of Calibrations (Best Measurement) |
For Data Loggers without probes fitted (Internal sensor)
| -24°C to 80°C | ±0.061°C in stirred liquid baths with comm block fitted. |
For Data Loggers with probes fitted (External sensor)
| -24°C to 130°C | ±0.056°C At single temperature points in dry block calibrator. |
| ±0.036°C At single temperature points in stirred liquid baths. |
Relative Humidity Calibrations & Re-Calibration to loggers
| Calibration Temperature Range | Least Uncertainty of Calibrations (Best Measurement) |
Single humidity points between 12% and 85% RH
| -12% to 85% RH | ±1.0% RH at a dry bulb temperature between 20°C and 30°C and a dew point range of -6°C to 23°C |
Calibration over the entire range from 12% to 85% R
| 12% to 85% RH | 3.0% RH at a dry bulb temperature between 20°C and 30°C and a dew point range of -6°C to 23°C |